Quantcast AIR SHUTOFF SOLENOIDS

Custom Search
 
  
 
3500 ENGINE ATTACHMENTS
SPECIFICATIONS
AIR SHUTOFF SOLENOIDS
6T4751 Solenoid (G. W. Lisk, W-1080-2)
Voltage rating ................................................... 24 to 32V
Coil resistance at 25 C (77 F) .............. 3.3 to 4.1 ohms
Activate to  ......................................................... shutoff
NOTICE
This solenoid must not be used in constant
operation for more than 2.5 minutes or damage may
result.
Distance of plunger travel
..................................... 15.75 mm (.620 in.)
(2) Torque for terminal nuts
.............. 1.23 to 1.92 N-m (11 to 17 lb. in.)
9G8180 Solenoid (G. W. Lisk, W-1121-2)
Voltage rating ...................................................24 or 32V
Coil resistance at 25 C (77 F) .............. 3.3 to 4.1 ohms
Activate to  ......................................................... shutoff
NOTICE
This solenoid must not be used in constant
operation for more than 2.5 minutes or damage may
result.
(1)
Distance of plunger travel.... 15.75 mm (.620 in.)
(2)
Tighten shaft nut to a
torque of .................... 24 + 7 Nm (18 + 5 lb. ft.)
(3)
Torque for terminal
nuts .............. 1.23 to 1.92 N-m (11 to 17 lb. in.)
456


 