TM   5-2815-241-34&P FUEL INJECTOR - CONTINUED ACTION LOCATION ITEM REMARKS 100. Injector (15) Orifice  plug  (16) and  gasket  (17) Using  5/64-inch  hex  key,  remove  orifice plug. Discard   gasket. 101. Orifice  plug  (16) Using  orifice  size  gage  ST-1332,  measure orifice plug at the base end, not the wrench   end. NOTE Compare orifice plug inside diameter to table on page 2-380. Choose new orifice plug with inside diameter one size smaller than orifice plug removed. T A    2 4 2 5 9 3 2-379


 