TM   5-2815-241-34&P CRANKSHAFT  INSTALLATION  -  CONTINUED Step 1 Step  2 Step  3 Step  4 Step  5 MAIN  BEARING  CAPSCREW TORQUING   SEQUENCE MIN   FT/Lbs(kgml   MAX   FT/Lbs(kgm) Tighten  to 140 (19,4) 150  (20,7) Advance  to 300  (41,5) 310  (42,9) Loosen  to 0 0 Tighten  to 140  (19,4) 150 (20,7) Advance  to 300  (41,5) 310  (42,9) TA  242373 2-57


 