Quantcast ENGINE STARTS BUT FAILS TO KEEP RUNNING.

Custom Search
 
  
 
ARMY   TM   9-2805-262-14 AIR  FORCE  TO  38G2-90-1 NAVY  NAVFAC  P-8-613-14E Table 3-1. Operator Troubleshooting Procedures (cont). Malfunction Test  or  Inspection Corrective  Action 3. ENGINE STARTS BUT FAILS TO KEEP RUNNING. NOTE If engine is warm, the choke may not need to be closed completely. Step  1.  Check  choke  position. If engine is cold, close  choke. If engine is warm, close choke Step 2. Check fuel shutoff valve. halfway. Turn  valve  counterclockwise  to  open. If engine still fails to keep running, notify unit maintenance. 3-3/(3-4  blank)


 