(2) (3) TM9-2815-202-34 Air pressure at outlet port elbow (23) should be 10 psi at 18 V dc. Pump should draw a maximum of 25 amperes. Remove power source from terminals (13 and 14). f.   Installation (1) Install adapter (22) to elbow (23). (2) Position air pump (5), cushion (19), and air pump clamp (18) on bracket (20). Install bolt (15), Iockwasher (16), and flat washer (17). Torque bolt to 35-39 Ib-ft (47-53 N-m). (3) Install hose (21) and check valve (2) onto adapter (22). (4) Connect hose (1) to check valve (2). (5) Connect hose (3) onto elbow (4) of air pump (5). NOTE Only model 7083-7396 has clamp (6) on hose (3) and uses an elbow (7) instead of an adapter (7). (6) (7) If removed, install adapter (7) and clamp (6) on hose (3). Secure clamp to governor cover using  screw  assembly  (8). Connect large wiring harness lead (12) to terminal (13) marked (+) on air pump (5) and secure with nut (9). Connect wiring harness lead (11 ) to terminal (14) on pump and secure with nut (10). 4-25


 