TM9-2815-202-34 e.  Installation (1) (2) (3) (4) (5) (6) Install gasket (11) onto accessory drive assembly (5). Install fiber coupling (9) onto blower drive hub (10). Aline accessory drive assembly (5) with slots  in  fiber  coupling. Install accessory drive assembly (5) onto flywheel housing (6). Install two bolts (8) and two Iockwashers  (4). Install three bolts (7) and three Iockwashers (4). Install bolt (1), flat washer (3), Iockvvasher (4), and nut (2). Torque two bolts (8) to 30-35 Ib-ft (41-47 N-m). Torque three bolts (7) and bolt (1) to 35-39 Ib-ft (47-53 N-m). END OF TASK 5-19


 