Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR REPLACEMENT (300 AMPHERE)
0052 00
REMOVAL (Continued)
2. Disconnect positive polarity wiring.
a. Remove self-locking nut (7) with flat washer (8) to disconnect electrical cable (9) and
electrical leads (10) and (11). Reinstall self-locking nut and flat washer.
b. Remove self-locking nut (12) with flat washer (13) to disconnect electrical lead (14).
Reinstall self-locking nut and flat washer.
c. Remove self-locking nut (15) with flat washer (16) to disconnect electrical lead (17).
Reinstall self-locking nut and flat washer.
12, 13
14
7, 8
15, 16, 17
9, 10, 11
10
9
11
17 14
WP 0052 00-2

 