TM 9-2815-220-24
SIGNAL WIRING HARNESS REPLACEMENT (2CA) (PN 12254376, 12354385) 0057 00
REMOVAL (Continued)
3. Remove lower retaining straps (9).
a. Remove four screws (10) with lock washers (11) and remove two retaining straps (9).
Discard lock washers.
4. Remove electrical connector (12) at right manifold heater exciter (13).
12
10, 11
(four places)
13
9
5. Remove loop clamp (14).
a. Remove screw (15) with lock washer (16). Discard lock washer.
b. Remove loop clamp (14).
14
15, 16
WP 0057 00-2

 