Custom Search
 
  
 
TM 9-2815-220-24
SIGNAL WIRING HARNESS REPLACEMENT (2DA) (PN 12254376, 12354385) 0058 00
INSTALLATION (Continued).
6. Install harness to low voltage protection module (LVPM) mounted on top of engine.
a. Remove nut (91) and lock washer (92) from starter positive lug.
b. Install LVPM module wire (93) to starter positive lug with existing nut (90) and lock
washer (92).
c. Install LVPM lead (96) with machine screw (94) and lock washer (95).
93
96
94, 95
91, 92
d. Install loop clamp (90) onto cable (s).
e. Install screw (88) with new lock washer (89) (item 93, WP 0175).
90
88, 89
WP 0058 00-20

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business