SIGNAL WIRING HARNESS REPLACEMENT (2DR) (PN 11671816, 10887570) 0059 00
INSTALLATION (Continued)
2. Install screw (56) and new lock washer (57) (item 93, WP 0175) to secure ground lead (58) for
automatic water drain control module (55).
3. Connect lead (54) at automatic water drain control module (55).
4. Install loop clamps (51) with screws (52) and new lock washers (53) (item 93, WP 0175).
5. Connect lead at governor solenoid (48), fuel shutoff connection (49), and flame heater
solenoid (50).
51, 52, 53
49
48
50
54
58
56, 57
55
51, 52, 53
WP 0059 00-10

 