TM 9-2815-220-24
GENERATOR WIRING HARNESS REPLACEMENT (2DA) (PN 11682723)
0064 00
INSTALLATION (Continued).
2. Install lower retaining straps (9).
a. Position harness into retaining straps (9).
b. Install four screws (10) with new lock washers (11) (item 92, WP 0175).
10, 11
(four places)
9
3. Position harness into loop clamp (12).
a. Install loop clamp (12) using screw (13) with new lock washer (14) (item 93, WP 0175).
12
13, 14