Custom Search
 
  
 
TM 9-2815-220-24
OIL SAMPLING SYSTEM REPLACEMENT (2CA, 2DA)
0070 00
CLEANING
See Work Package 0028 for Standard Cleaning Procedures.
INSPECTION
All parts must be inspected with care. Replace parts if damage or wear exceeds allowable
limits.
1.
See Work Package 0028 for Standard Inspection Procedures.
2.
Assure that activation handles of oil sampling valves are secure. If handles are loose or
damaged, replace valve.
3.
Inspect oil sampling valves for opening and closing action. Valves must open and close
freely; if not, replace valve.
4.
Check that valves do not leak. Replace any valve that leaks.
ASSEMBLY
1. Install valves (11, 12) in bracket (10).
a. With bracket (10) clamped in a vise, position valves (11,12) as shown (with the handles
and inlet ports facing opposite each other and parallel to bottom flanges of the mounting
bracket).
b. Secure both valves (11,12) in mounting bracket (10) by tightening locking nut (17) on each
valve.