Quantcast INSTALLATION (Continued) - TM-9-2815-220-240814

Custom Search
 
  
 
TM 9-2815-220-24
TURBOSUPERCHARGER ASSEMBLY REPLACEMENT (2DR)
0100 00
INSTALLATION (Continued)
2. Install exhaust pipes (23).
a. Lubricate six screws (26) with antiseize compound (item 5, WP 0173).
b. Position two new exhaust gaskets (27) (item 327, WP 0175).
c. Secure exhaust pipes (23) to turbosupercharger housing (16) using six new self-locking
nuts (24) (item 161, WP 0175), flat washers (25), and screws (23). Do not tighten screws
at this time.
24, 25 (6 places)
16
23
26 (6 places)
27
23
WP 0100 00-8

 