Quantcast REMOVAL - TM-9-2815-220-241324

Custom Search
 
  
 
TM 9-2815-220-24
GENERATOR DRIVE MECHANISM REPLACE/REPAIR (650 AMPERE)
0156 00
REMOVAL
1. Remove generator end plate (1).
a. Remove six screws (2).
b. Remove generator end plate (1) and gasket (3) from generator drive adapter (4). Discard
gasket.
4
3
1
2
2. Remove generator drive adapter (4).
a. Remove five screws (5) with lock
washers (6). Discard lock washers.
b. Remove one self-locking nut (7) with flat
washer (8). Discard self-locking nut.
8
c. Remove generator drive adapter (4) and
7
gasket (9). Discard gasket.
9
4
6
5
WP 0156 00-2

 