Custom Search
 
  
 
TM 9-2815-220-24
ACCESSORY DRIVE HOUSING REPLACE/REPAIR
0158 00
INSTALLATION (Continued)
2x
NOTE
One of the 29 self-locking nuts (2x)
with flat washers that secure the
accessory drive housing will be
installed when the fire extinguisher
tube is installed. Two of the self-
locking nuts are accessed from
underneath the accessory base
assembly.
4. Attach accessory drive assembly (1).
a. Install 24 new self-locking nuts (2)
(item 140, WP 0175) with flat
washers (3).
2 (2 places)
3
4
b. Install two new self-locking nuts (2)
(item 140, WP 0175) with flat
2 (24 places)
washers (3) and new seal washers (4)
3
(item 194, WP 0175). (Left side
illustrated; right side is mirror image).
8
c. Install two new self-locking nuts (2)
9
(item 140, WP 0175) with flat
washers (3) from bottom side of
housing (1). (Left side illustrated;
1
right side is mirror image).
d. Torque-tighten 28 self-locking nuts (2)
to 23-25 foot-pounds (31-34 Nm).
END OF WORK PACKAGE
3
2
WP 0158 00-22

 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business