Quantcast TEST INJECTOR

Custom Search
 
  
 
TM 9-2815-226-34-2
3-75. TEST INJECTOR
a. Prepare injector for plunger-to-barrel leakage test, check ball leakage test, and plunger-to-cup tip leakage check
using 3375375 leakage tester:
(1) Remove injector inlet retainer and screen.
(2) Remove injector stopscrew, locknut, washer, and spring if installed.
(3) Lubricate O-rings on exterior of injector and insert injector into 3375395 adapter pot.
3-270


 