f. Perform fuel pump vacuum adjustment.
(1) Close stand bypass valve.
(2) Completely open stand suction control valve.
(3) Depress stand FAST button until fuel pump speed is 2000 rpm.
NOTE
When the suction control valve setting is reached, the valve setting must not be
changed during later calibration procedures.
(4) Adjust suction control valve to obtain 8.0 in. Hg (4 psi) reading on no. 2 vacuum gage.