TM 9--2815--247--34 0073 00--3 CAMSHAFT ASSEMBLY LEFT BANK REPAIR -- CONTINUED 0073 00 Inspection -- Continued 6.   Check maximum runout of center journal (13) with dial indicator (12) against the following limits. REF NO. POINT OF MEASUREMENT SIZES AND FITS OF NEW PARTS inches (mm) WEAR LIMITS 13 Maximum runout of center journal when supported on end bearing (full indicator reading) 0.0020 (0.0508) 0.0150 (0.381) Figure 10 12 13 7.   Measure camshaft lobe (7) lift with dial indicator (12) against the following limits. REF NO. POINT OF MEASUREMENT SIZES AND FITS OF NEW PARTS inches (mm) WEAR LIMITS 7 Camshaft lobe lift 0.4170 (10.5918) 0.4230 (10.7442) 0.4140 (10.5156) Figure 10 7 12


 