TM 9--2815--247--34 0089 00--2 METERING PUMP BASE AND ASSOCIATED PARTS REPLACEMENT -- CONTINUED 0089 00 Installation 1.   Apply sealant to new preformed packing (4). 2.   Install new preformed packing (4) on tube in crankcase. Figure 35 4 3.   Install bracket (3) on crankcase. 4.   Lubricate four screws (1) with lubricant. 5.   Secure bracket (3) with four screws (1) and four new lockwashers (2). 6.   Tighten four screws (1) to 56--60 lb--ft (76--82 NSm). Figure 35 1 2 3 NOTE FOLLOW--ON MAINTENANCE: Install mechanical drive housing and associated parts (fan tower, damper end) (WP 0096 00) Install fuel metering pump assembly (WP 0039 00) END OF TASK


 