ARMY TM 9-2815-259-24 AIR FORCE TO 38G1-125-2 MARINE CORPS 09249A/09246A-24 4-34 (n)     Using a multimeter, touch one probe to field winding end of brush and other one to bare surface of yoke body, refer to Figure 4-31.  There should be no continuity.  If there is continuity, field windings are grounded.  Replace the yoke assembly. FIGURE 4-31.  CHECKING FIELD COILS (o)     Using a multimeter, touch one probe to lead wire and other one to brush, refer to Figure 4- 32.  There should be continuity.  If there is no continuity, field windings are open circuited. Replace the yoke assembly. FIGURE 4-32.  CHECKING FOR OPEN FIELD COIL


 