Custom Search
 
  
 
ARMY TM 9-6115-666-13&P
AIR FORCE TO 35C2-3-505-1
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-1612 andAN/MJQ-1632
Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
GENERATOR SET -
continued
33
Before
CONTROL BOX
Check for loose or damaged
Loose or damaged wires.
HARNESS
wiring.
34
Before
GROUND ROD
Inspect ground rod and cable
Cable is missing or damaged.
CABLE AND
for loose connections, breaks,
CONNECTION
damage and corrosion.
WARNING
ENSURE generator set is properly grounded prior to starting. Otherwise
serious injury or death could result by electrocution.
35
Before
PARALLEL CABLE
Inspect parallel cable for
Cable is damaged.
damage.
36
Before
CABLE ASSEMBLY
Inspect cable assembly for
Cable is damaged.
damage.
Any leaks, damaged, loose or
37
Before
AUXILIARY FUEL
Inspect auxiliary fuel system
missing parts.
SYSTEM
for leaks, damaged, loose or
missing parts
38
During
SWITCH BOX
Check indicator lights. Ensure
ASSEMBLY
indicator lights are operating
properly.
Cannot secure door.
39
During
HOUSING
a. Check doors, hinges, and
latches for damage, loose,
or corroded items.
b. Inspect air intake and
Grills plugged; air flow cut off
exhaust grills for debris.
WARNING
With any access door open, the noise level of this generator set could
cause hearing damage. Hearing protection must be worn when working
near the generator set while running.
2-23


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business