COOLING SYSTEM
SYSTEMS OPERATION
enough to make the regulators start to open, coolant flow
in the bypass line is stopped and coolant is sent through
the outlets to the radiator or heat exchanger.
Total system coolant capacity will depend on the
size of the heat exchanger. Use a coolant mixture of 50
percent pure water and 50 percent permanent antifreeze,
then add a concentration of 3 to 6 percent corrosion
inhibitor.
TOP OF ENGINE
6. Water manifolds. 7. Aftercooler. 11. Exhaust
manifolds.
RIGHT SIDE OF ENGINE
1. Water pump. 3. Oil cooler. 10. Bypass tube.
WATER TEMPERATURE REGULATOR HOUSINGS
6. Water manifolds. 8. Regulator housing. 10. Bypass
tube. 12. Regulator housing. 13. Housing.
FRONT OF ENGINE
1. Water pump. 3. Oil cooler. 10. Bypass tube.