Tweet |
Custom Search
|
|
|
||
HYDRAMECHANICAL PROTECTIVE SYSTEM
SPECIFICATIONS
SHUTOFF CONTROL GROUP
(1) Torque for 6K9194 Elbow...11 3 Nm (8 2 lb. ft.)
(2) Torque for 321267
Connectors .................................11 3 Nm (8 2 lb. ft.)
(3) Torque for 5M6213 Plugs...11 3 Nm (8 2 lb. ft.)
(4) Torque for 321268 Elbows ...113 Nm (8 2 lb. ft.)
(5)
Spring for overspeed
adjustment:
See
OVERSPEED SPRING CHART.
OVERSPEED SPRING CHART
Part No.
7B7714
2N7029
5N5297
Length under
18.3 mm
31.0 mm
20.3 mm
test force
(.72 in.)
(1.22 in.)
(.80 in.)
16 .05 N
Test force
34.7 to 40.9 N
18 N
(3.6 .1 lb.)
(7.8 to 9.2 lb.)
(4 lb.)
Free length
33.7 mm
50.0 mm
37.3 mm
after test
(1.33 in.)
(1.97 in.)
(1.47 in.)
Outside
11.94 mm
9.53 mm
9.22 mm
diameter
(.470 in.)
(.375 in.)
(.363 in.)
Used with
5N5328
Shutoff
5N 1960
5N5329
5N5330
Control
5N5608
5N6051
5N5338
Group
5N6050
(6)
Dimension from end of speed sensing valve to the
seat ................ 117.21 0.25 mm (4.615 .010 in.)
(7)
Torque for eight cover
bolts........................... 3.4 0.5 N-m (31 4 lb. in.)
(8)
Speeder Spring:
See SPEEDER SPRING
CHART.
(9)
Thickness of geroter
assembly .. 25.000 0.006 mm (.9843 .0002 in.)
Depth of
counterbore25.033 0.006 mm (.9856 .0002 in.)
(10) Diameter of
shaft ......... 14.750 0.013 mm (.5807 .0005 in.)
Diameter of bore
in cover..... 14.801 + 0.013 mm (.5827 .0005 in.)
(11) Diameter of
shaft ......... 12.000 + 0.013 mm (.4724 .0005 in.)
Diameter of bore
in housing.........12.051 4 0.013 (.4744 .0005 in.)
203
|
||