Custom Search
 
  
 
3500 ENGINE ATTACHMENTS
SPECIFICATIONS
TIME DELAY RELAY
5N2124 (Dynalco Corp. Number DSC-9)
Operating voltage range ...............................8 to 40 VDC
On Delay.
Control 1 ..........No delay on setting (O seconds)
Control 2 ........... 8 to 10 second delay on setting
Off Delay.
60 to 80 second delay on resetting
JACKET WATER HEATERS
5N5739 120 VAC, 3000 Watts
5N5740 240 VAC, 3000 Watts
(1)
Thermostat adjustment
........... 16 to 82 C (60 to 180 F)
range
(2)
Coolant inlet
(3)
Coolant outlet
MAGNETIC PICKUP
(1)
Distance between end of magnetic
pickup and gear
............... 0.56 to .085 mm (.022 to .033 in.)
(2)
Nut. Tighten nut to a
torque of ................... 45 + 7 N-m (33 + 5 lb. ft.)
NOTE: FOR TORQUE VALUES NOT GIVEN, SEE THE FIRST
PAGE OF SPECIFICATIONS FOR GENERAL TIGHTENING TORQUES