TM 5-2815-241-34&P
VALVE AND INJECTOR ADJUSTMENTS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
3.
Injector plunger (6)
Using crankshaft barring tool, rotate en-
gine and check dial indicator (5) reading
for plunger-free travel not exceeding
0.206 inch (5.3 mm).
NOTE
If plunger-free travel exceeds 0.206 inch (5.23 mm), torque method of adjustment
(steps 17 thru 23) must be used.
ST-1170 dial
If injector free travel is within limits, pro-
indicator (5)
ceed to adjustment procedures.
Adjustment
NOTE
During repairs, injectors and valves are cold set with temperature of oil and component
parts within 10oF (-11°C) of ambient air room temperature. Final hot-set adjustments
will be made on engine test stand. See Final Testing, Adjustments, and Troubleshoot-
ing on Engine Test Stand (page 2-414).
The following injector and valve adjusting procedures and Engine Specifications (page
2-434) require injectors be adjusted before valves.
T A 2 4 2 4 0 0
2-107
|
|