Custom Search
 
  
 
TM   5-2815-241-34&P VALVE  AND  INJECTOR  ADJUSTMENTS  -  CONTINUED ACTION LOCATION ITEM REMARKS 3. Injector   plunger   (6) Using  crankshaft  barring  tool,  rotate  en- gine and check dial indicator (5) reading for plunger-free travel not exceeding 0.206 inch (5.3 mm). NOTE If  plunger-free  travel  exceeds  0.206  inch  (5.23  mm),  torque  method  of  adjustment (steps  17  thru  23)  must  be  used. ST-1170   dial If injector free travel is within limits, pro- indicator   (5) ceed  to  adjustment  procedures. Adjustment NOTE During repairs, injectors and valves are cold set with temperature of oil and component parts within 10oF (-11°C) of ambient air room temperature. Final hot-set adjustments will be made on engine test stand. See Final Testing, Adjustments, and Troubleshoot- ing  on  Engine  Test  Stand  (page  2-414). The  following  injector  and  valve  adjusting  procedures  and  Engine  Specifications  (page 2-434)  require  injectors  be  adjusted  before  valves. T A    2 4 2 4 0 0 2-107


 