TM 5-2815-241-34&P
CYLINDER BLOCK - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING/INSPECTION
Particles blown by compressed air are hazardous. Make certain the airstream is di-
rected away from user and other personnel in the area. Compressed air used for
cleaning purposes shall not exceed 30 psi (207 kPa). User must wear safety goggles or
face shield to prevent injury.
Drycleaning solvent P-D-680 is toxic and flammable. Wear safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do
not breathe vapors. Do not use near open flame or excessive heat. Flash point for Type
#1 Drycleaning Solvent is 100oF (38°C) and for Type #2 is 138° F (59° C). If you become
dizzy while using solvent, get fresh air immediately, and get medical aid. If contact with
eyes is made, wash your eyes with water and get medical aid immediately. Failure to
observe these precautions could cause serious injury or death to personnel.
NOTE
For general cleaning procedures, see General Maintenance Instructions, page 2-3.
10.
Cylinder block (1)
a.
Using compressed air, clean water
pump air bleed hole (2) in number one
cylinder bore (3).
b.
Using compressed air, blow all dirt and
cleaning solvent from all capscrew
holes (4).
c.
Remove scale from sleeve counterbore
ledge (5).
d.
Using emery cloth, clean lower sleeve
bore (6).
TA 242428
2-143
|
|