Custom Search
 
  
 
TM    5-2815-241-34&P CYLINDER  BLOCK  -  CONTINUED ACTION LOCATION ITEM REMARKS CLEANING/INSPECTION Particles blown by compressed air are hazardous. Make certain the airstream is di- rected away from user and other personnel in the area. Compressed air used for cleaning  purposes  shall  not  exceed  30  psi  (207  kPa).  User  must  wear  safety  goggles  or face shield to prevent injury. Drycleaning solvent P-D-680 is toxic and flammable. Wear safety goggles and gloves and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do not use near open flame or excessive heat. Flash point for Type #1  Drycleaning  Solvent  is  100oF  (38°C)  and  for  Type  #2  is  138°  F  (59°  C).  If  you  become dizzy while using solvent, get fresh air immediately, and get medical aid. If contact with eyes is made, wash your eyes with water and get medical aid immediately. Failure to observe  these  precautions  could  cause  serious  injury  or  death  to  personnel. NOTE For general cleaning procedures, see General Maintenance Instructions, page 2-3. 10. Cylinder  block  (1) a. Using  compressed  air,  clean  water pump  air  bleed  hole  (2)  in  number  one cylinder  bore  (3). b. Using compressed air, blow all dirt and cleaning  solvent  from  all  capscrew holes  (4). c. Remove   scale   from   sleeve   counterbore ledge  (5). d. Using emery cloth, clean lower sleeve bore (6). TA   242428 2-143


 