TM 5-2815-241-34&P
CYLINDER BLOCK - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
d.
Using dial bore gage, measure cylinder
sleeve inside diameter, C.
If diameter is greater than 5.505 inch
(139.83 mm), discard cylinder
sleeve.
e.
Inspect for scoring or vertical grooving
on inside bore.
If scores or grooves cannot be re-
moved during deglazing, discard
cylinder sleeve.
f.
Deglaze cylinder sleeves that have
passed checks and inspections.
WARNING
Particles blown by compressed air are hazardous. Make certain the air stream is
directed away from user and other personnel in the area. Compressed air used for
cleaning purposes shall not exceed 30 psi (207 kPa). User must wear safety goggles or
face shield to prevent personnel injury.
NOTE
After cylinder sleeves are deglazed, clean thoroughly with compressed air to remove all
particles from cylinder sleeve. Coat bores with lubricating oil after cleaning.
TA 242431
2-149
|
|