TM 5-2815-241-34&P
CYLINDER HEAD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REPAIR/ASSEMBLY - CONTINUED
NOTE
Steps 49, 50, and 51 are typical for all cylinder head valves requiring refacing.
Valve refacer operating instructions are provided with the valve refacer machine.
49.
50. Valve refacer
Valve (1)
Insert valve stem in valve refacer chuck on
guide area of stem (2).
Valve (1)
a.
Check valve for out-of-round condition.
If runout exceeds 0.001 inch (0.03
mm), valve is warped. Discard valve.
b.
Using ST-685 valve seat grinder, wet
grind valve to an exact 30-degree angle
from horizontal, just enough to reface
completely around the valve head.
If after grinding, valve head thickness
(3) Is less than 0.105 Inch (2.67
mm), discard valve.
c.
Compare refaced valve to the following
table.
VALVE SPECIFICATIONS
ITEM
INTAKE AND
NEW MINIMUM
NEW MAXIMUM WORN LIMITS
EXHAUST VALVES
2
stem
3
valve head
thickness
4
seat angle
5
refacing valve
seating area
0.4500 inch (11.4300 mm)
0.105 inch (2.67 mm)
30 degrees
0.0625 inch (1.59 mm)
0.4510 inch
(11.4554 mm)
30 degrees
0.4490 inch
(11.4046 mm)
0.105 inch
(2.67 mm)
0.0625 inch
(1.59 mm)
2-206
|
|