TM 5-2815-241-34&P
PISTON AND CONNECTING ROD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
NOTE
Procedure for checking connecting rods is typical for use of the ST-561 connecting rod
checking fixture.
18. ST-561 connecting
rod checking
fixture (7)
Holder plate
knob (8)
a. Loosen.
Raise high enough so piston pin
mandrel (5) will clear Indicator pins
(9) when installed.
b.
Raise holder plate (10) and retighten
holder plate knob.
19.
20.
21.
Master connecting
rod (1)
Position in checking fixture by seating
expanding arbor (6) in base (11) and piston
pin mandrel (5) against frame (12).
Holder plate
knob (8)
a.
Loosen and slowly lower holder plate
(10) until indicator pins (9) just seat on
piston pin mandrel (5).
b. Tighten holder plate knob securely.
Two dial
indicators (13)
Set dials to zero.
T A 2 4 2 4 9 3
2-227
|
|
|
|