TM 5-2815-241-34&P
ROCKER ARM HOUSING AND PUSH ROD - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION - CONTINUED
NOTE
Steps given are typical for all push rods.
16.
Push rod (1)
17.
18.
a.
Wipe clean with rag and inspect for
cracks and bends.
If cracked or bent, replace.
b.
Coat ball end of adjusting screw (2)
with prussian blue.
c.
Place ball end of adjusting screw (2)
into push rod socket (3) and rotate
using hand pressure.
d.
Check push rod socket (3) wear area.
If push rod socket (3) wear area is
not 80-percent blued, replace push
rod.
Push rod (1)
NOTE
a.
Using 5/16-inch radius gage, check ball
end (4) for wear.
If ball end (4) diameter is not 0.623
to 0.625 inch, replace push rod.
b.
Check for loose push rod socket ends
(3) or ball ends (4).
If socket ends or ball ends are loose,
replace push rod.
Steps given are typical for adjusting screws and adjusting bolts.
Six adjusting
screws (5) and six
new locknuts (6)
Wipe clean and screw locknut down full
length of threads by hand.
If locknut binds on threads, replace
adjusting screw or adjusting bolt (7).
2-248
|
|