TM  5-2815-241-34&P FUEL  PUMP  -  CONTINUED ACTION LOCATION ITEM REMARKS SHUTDOWN  VALVE  REPAIR NOTE For  shutdown  valve  removal  procedures,  see  step  5,  page  2-292. 42. Shutdown valve housing   (1) Four  machine  screws Using 1/4-inch flat-tip screwdriver, un- (2)  and  four  lock- screw  and  remove. washers  (3) Discard    lockwashers. 43. 44. 45. 46. 47. 48. Coil  assembly  (4) Remove. Access cover plate (5),  spring  washer (6),  preformed  pack- ing  (7),  disk valve (8) Remove. Discard   packing. Override  knob  (9) Pull  off. Shaft  (10),  pre- formed  packing  (11) and  O-ring  (12) Using   1/4-inch   flat-tip   screwdriver,   un- screw and remove shaft and preformed packing from coil end. Discard  shaft,  preformed  packing and  O-ring. Pipe plug (13) Using   7/16-inch   open-end   wrench,   un- screw  and  remove. CAUTION Do not wet coil assembly with solvents or cleaners. Solvents or cleaners will cause damage to coil. NOTE For  general  cleaning  procedures,  see  General  Maintenance  Instructions,  page  2-3. Coil  assembly  (4) Using  ohmmeter,  check  coil  resistance. Resistance should be 7.5 ohms ± 0.5 ohms. 2-304


 