Custom Search
 
  
 
TM  5-2815-241-34&P FUEL PUMP CALIBRATION - CONTINUED ACTION LOCATION ITEM REMARKS REMOVING  PUMP  FROM  TEST  STAND  -  CONTINUED 41.  Test  stand  (1) Fuel   pressure Remove from test stand pressure gage outlet hose  (2) (3)  and  fuel  pump  discharge  fitting  (4). 42. Fuel  pump  discharge fitting (4) Remove  fuel  pump  discharge  fitting  from fuel  pump  shutdown  valve  (5). 43. 1/4-inch  (6.35  mm) clear  manifold hose  (6) Remove  from  no.  2  manifold  vacuum  gage (7)  and  1/4-inch  (6.35  mm)  adapter  on pump  inlet  adapter  assembly  (8). 44. 1/2-inch  (12.7  mm) flexible  hose  (9) Remove from test stand suction control valve (10)  and  adapter  elbow  on  pump  inlet adapter  assembly  (8). 45. Pump  inlet  adapter assembly  (8) Remove  from  pump  inlet  port  (11). 46.  Fuel  pump  (12) Fuel  filter  adapter (13)  and  gasket  (14) Remove. 47. Fuel shutdown valve manual  override knob  (15) Close  fully  by  turning  counterclockwise. 48.  Test  stand  (1) Fuel pump (12) four screws  (16)  and  four lockwashers   (17) 49. Fuel  pump  (12) a. Remove  four  screws  and  four  lock- washers  from  fuel  pump  and  ring  adapter assembly  (18). b. Remove fuel pump from test stand. Plug all fuel pump ports to prevent entry of dirt  and  foreign  matter. 2-350


 