TM   5-2815-241-34&P FUEL INJECTOR - CONTINUED ACTION LOCATION ITEM REMARKS CAUTION Injector barrel and plunger are a matched set (class fit). Do not interchange. Do not touch internal parts unless hands are clean and moistened with fuel oil. Acids from  skin  can  corrode  internal  parts  and  affect  their  close  tolerances. 2. Plunger  (3)  and spring  (4) Pull out from injector. Store  plunger  by  standing  on  coupling end. 3. Preformed  packing (5) and two gaskets  (6) Roll  off  injector  (1). Discard  packing  and  gaskets. 4. Strainer  element clip  (7)  and  strainer element  (8) Remove  and  inspect  for  damage. Discard  if  damaged. T A    2 4 2 5 7 2 2-353


 