TM 5-2815-241-34&P
FUEL INJECTOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CAUTION
Injector barrel and plunger are a matched set (class fit). Do not interchange.
Do not touch internal parts unless hands are clean and moistened with fuel oil. Acids
from skin can corrode internal parts and affect their close tolerances.
2.
Plunger (3) and
spring (4)
Pull out from injector.
Store plunger by standing on coupling
end.
3.
Preformed packing
(5) and two
gaskets (6)
Roll off injector (1).
Discard packing and gaskets.
4.
Strainer element
clip (7) and strainer
element (8)
Remove and inspect for damage.
Discard if damaged.