TM 5-2815-241-34&P
FUEL INJECTOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
NOTE
When testing check ball seating, hold injector in hand. Do not place in ST-790 injector
test stand holding device.
78. Injector (2)
79. ST-790 injector
test stand (9)
Plunger (1)
Motor switch (10)
Hold plunger down in injector.
Place in start position.
Check temperature gage (11). Test
oil testing temperature should be 90°
to 95°F (32° to 35°C).
80.
Regulator knob (12)
81.
ST-708 burnishing
tool adapter orifice
plug opening (14)
82.
83.
Adjust by turning until pressure gage (13)
reads 150 psi (1034 kPa).
Check for leakage. A slight see page of + 1 or
-2cc from the flow code stamped on the in-
jector is acceptable.
If leakage exceeds specifications,
replace check ball. See steps 1 thru 7
and 17 thru 27.
Motor switch (10)
ST-790 injector test
stand inlet line (7)
and drain line (8)
Place in stop position.
Disconnect from ST-708 burnishing tool
adapter (5).
T A 2 4 2 5 9 0
2-375
|
|