TM 5-2815-241-34&P
FUEL INJECTOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
TESTING - CONTINUED
93. ST-790 injector
test stand (1)
94.
95.
96.
97.
98.
Air valve (2)
Open to clamp injector in place.
Make sure ST-790 injector test stand
link is alined.
Hydraulic valve (3)
Close to lock injector in place.
Motor switch (4)
Place in start position.
Check temperature gage (5). Test oil
testing temperature should be 90° to
95°F (32° to 35°C).
Regulator knob (6)
Adjust by turning until pressure gage (7)
reads 120 psi (827 kPa).
Flow start
switch (8)
Press in until counter (9) reads the same
number of strokes as ST-1210 master
injector.
Vial (10)
Observe reading.
Correct reading Is 182 to 183 cc at 120
psi (827 kPa).
NOTE
If vial reading Is greater than 183 cc, proceed with steps 99 thru 103 to install new orifice
plug, and recheck delivery steps 95 thru 98. If vial reading is less than 182 cc, proceed
with steps 103 and 104 to burnish orifice plug, and recheck delivery steps 95 thru 96.
If vial reading is correct at 182 to 183 cc, proceed with steps 105 thru 113.
99. ST-708 burnishing
tool adapter (11)
Injector inlet con-
nectar (12) and
burnishing tool (13)
Remove by turning large knob section (14)
out until assembly is free.