TM 5-2815-241-34&P
FINAL TESTING AND ADJUSTMENTS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
13.
ENGINE TESTING
14.
Engine mounted on
engine test stand
a.
Apply 12 volts to fuel shutdown valve (3)
to open.
b.
Start engine (page 2-3). Allow to idle at
approximately 800 rpm.
If engine gives no Indication of
starting, see engine test stand
troubleshooting, page 2-424.
Engine mounted on
engine test stand
a.
Operate at 800 rpm for 5 to 10 minutes.
b. Check oil pressure.
Shut down engine if not between 10
and 70 psi, and correct fault. See
engine test stand troubleshooting,
page 2-424.
c.
Restart engine (page 2-3).
d. Check water temperature.
Shut down engine If above 200°F
(93°C) and correct fault. See engine
test stand troubleshooting,
page 2-424.
e.
Restart engine (page 2-3).
f.
Check all filters, gaskets, connections,
and hoses for leaks.
Shut down engine, repair or replace
all leaking filters, gaskets, connec-
tions, and hoses.
g.
Restart engine (page 2-3).
h.
Shut down engine. Check oil level.
Refill to high mark.
T A 2 4 2 6 1 5
2-419
|
|