TM   5-2815-241-34&P FINAL   TESTING   AND   ADJUSTMENTS   -   CONTINUED ACTION LOCATION ITEM REMARKS 13. ENGINE  TESTING 14. Engine   mounted   on engine  test  stand a. Apply  12  volts  to  fuel  shutdown  valve  (3) to  open. b. Start  engine  (page  2-3).  Allow  to  idle  at approximately 800 rpm. If  engine  gives  no  Indication  of starting,  see  engine  test  stand troubleshooting,   page   2-424. Engine   mounted   on engine  test  stand a. Operate  at  800  rpm  for  5  to  10  minutes. b. Check oil pressure. Shut  down  engine  if  not  between  10 and  70  psi,  and  correct  fault.  See engine  test  stand  troubleshooting, page  2-424. c. Restart  engine  (page  2-3). d.   Check   water   temperature. Shut down engine If above 200°F (93°C)  and  correct  fault.  See  engine test  stand  troubleshooting, page  2-424. e. Restart  engine  (page  2-3). f. Check  all  filters,  gaskets,  connections, and  hoses  for  leaks. Shut  down  engine,  repair  or  replace all  leaking  filters,  gaskets,  connec- tions,  and  hoses. g. Restart  engine  (page  2-3). h. Shut down engine. Check oil level. Refill to high mark. T A     2 4 2 6 1 5 2-419


 