TM 55-4920-436-13&P
2-9. Power shutdown.
a. See that all electrical tools and shop equipment
have been turned OFF.
b. Circuit breaker panel. Move main circuit breaker
(1) in the circuit breaker panel (2) from ON to OFF.
c. Disconnecting ECUs.
1. Place MODE SELECTOR switch (1) of ECU
(2) in OFF position.
2. Unscrew lock ring (3) and pull connector (4)
from ECU receptacle (5). Store cable (6) IAW TM 10-
5411-201-14.
3. Install cap (7) on receptacle (5).
2-25