Custom Search
 
  
 
1 2 3 4   5   6 4-22. DISASSEMBLE   LEFT   END   COVER   ASSEMBLY (SHEET  2  OF  4) Using   chisel   and   hammer, washer  (  1);  bend  tab  away straighten   bent   tab   of from   bolt   (2). Using   9/1   6   inch   socket,   install   two   1   /2-20   x   3   inch bolts   (3)   in   tapped   holes   at   either   end   of   output   flange (4). Using   one   hand,   hold   pry   bar   between   two   bolts   (3)   to prevent   flange   (4)   from   turning. Using   3/4   inch   socket   with   other   hand,   remove   bolt   (2) and   washer   (1)   from   output   flange   (4). Remove   output   flange   (4)   from   right   end   cover assembly   (5). Using  9/1  6  inch  socket,  remove  two  bolts  (3)  from output   flange   (4). FOLLOW-ON   PROCEDURE:   Install   output   flange. Refer  to  paragraph  4-24. End  of  Task  1 TASK   2.   REMOVE   LH   OUTPUT   SHAFT   AND   SEAL COMMON   TOOLS: Drift,   brass Hammer,   hand,   ball   peen Press,   arbor,   hand   operated Punch   drive   pin,   straight Screwdriver,   flat   tip   (2   required) SUPPLIES: Rag,   wiping   (Item   15,   Appendix   C) Wooden   Block,   2   x   4   inches   x   16   inches   long   (2   required) (Item   2,   Appendix   C) PRELIMINARY   PROCEDURE:   Left   end   cover   is removed.   Refer   to   paragraph   4-8. PERSONNEL   REQUIRED:   TWO   One   soldier   hold   end   cover   on   edge   for   removal   of output   shaft. One   soldier   use   hammer   and   punch   to   drive   shaft from   end   cover. Go  to  Sheet  3 Para.   4-22,   Task   2 TM  9-2520-272-34&P   4-149


 