Custom Search
 
  
 
TM 9-2520-272-34&P 4-23.  REPAIR LEFT END COVER COMPONENTS (SHEET 3 OF 3) NOTE Thread locking compound is not applied to    pipe    plug    that    has    a    preformed packing. 13 Install new packing (6) on pipe plug (5). 14 Apply petrolatum to packing (6). 15 Using  11/16  inch  socket,  install  plug  (5)  in  end cover (2). 16 Using torque wrench, tighten plug (5) to 72-96 lb- in.  (8-1 Nm). 17 Apply  pipe  thread  locking  compound  to  threads of six pipe plugs (1, 3, 4). 18 Using 9/16 inch socket, install four pipe plugs (4) in end cover (2). 19 Using torque wrench, tighten plugs (4) to 96-120 lb-in.  (11-14 Nm). 20 Using  7/16  inch  socket,  install  pipe  plug  (3)  in end cover (2). 21 Using torque wrench, tighten plug (3) to 50-60 lb- in.  (6-7 Nm). 22 Using   11/16   hex   plug   attachment,   install   pipe plug (1) in end cover (2). 23 Using   torque   wrench   and   attachment,   tighten plug (1) to 21-28 Ib-ft (28-38 Nm). 24 Using  a  1  inch  socket,  install  new  packing  (8) and plug (9) in end cover (2). 25 Using a torque wrench, tighten plug (9) to 16 - 18 lb ft (22 -24 Nm). FOLLOW-ON     PROCEDURE:     Assemble     end     cover assembly.  Refer to paragraph 4-24. End of Task 1 4-154  Change 2   Para.  4-23, Task 1


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business