Custom Search
 
  
 
TM   9-2520-272-34&P 4-30.   ASSEMBLE   CENTER   HOUSING (SHEET  12  OF  21) TASK   4.   INSTALL   HYDROSTATIC   PUMP   AND   MOTOR   ASSEMBLY COMMON   TOOLS: Adapter,   socket   wrench,   1/2   inch   female   square   drive,   3/8   inch   male   square   drive Extension,   socket   wrench,   3/8   inch   square   drive,   10   inch Handle,   socket   wrench,   3/8   inch   square   drive Hoist,   100   pound   minimum   capacity Pliers,   retaining   ring,   external Socket,   socket   wrench,   3/8   inch   square   drive,   9/16   inch Wrench,   torque,   0-175   Ib-ft SPECIAL    TOOLS: S-hook   (19207)   11650102 SUPPLIES: Eyebolt,    7/8-9 NOTE Transmission   installed   on   maintenance   stand with   input   housing   and   right   end   cover assemblies   removed,   right   end   of transmission    turned    up. 1   Install   32-tooth   hydrostatic   gear   (1)   on   end   of hydrostat   (2)   opposite   hydrostat   mounting   end,   with larger   shoulder   of   gear   out. 2   Using   external   retaining   ring   pliers,   install   retaining ring   (3)   to   hold   gear   (1)   on   hydrostat   (2). 3   Install   13-tooth   hydrostatic   drive   gear   (4)   on   hydrostat (2)   mounting   end,   with   shoulder   of   gear   out. 4   Using   external   retaining   ring   pliers,   install   retaining ring   (5)   to   hold   gear   (4)   on   hydrostat   (2). Go  to  Sheet  13 Para.   4-30,   Task   4 4-233


 