TM 9-2520-272-34&P
2-6. PRESSURE CHECKING PROCEDURES (Continued)
PRESSURE TEST
1 Locate desired pressure tap.
2 Remove plug. Screw gage
3 Start engine. Select
connector into port.
range and conditions
(see chart). Record
readings.
TA4485314
Plug
Port
Size
Name
(inch)
TV
7/16 hex
L U
9/16 hex
G1
7/16 ex
Plug torque values
Pluq size
lb-in.
Nom
7/16
50-60
6-7
9/1 6
96-100
11-14
Minimum Pressure
Shift
Port
Lever
Engine Speed
psi
kPa
TV
N
2500
91-97
627-669
L U
1-4*
2500
140-160
965-1103
GI
1-4*
2000
72-84
496-579
*vehicle operating on level, flat terrain.
4. After checking pressure identified in troubleshooting step, use test
results in the next block of instruction in the troubleshooting malfunction
sequence.
2-18
Para. 2-6
|
|