ARMY TM 9-2805-256-14
AIR FORCE TO 38G2-102-2
NAVY NAVFAC P-8-611-14E
5-8.
c.
Governor Assembly (cont).
Repair. Breaker Point Ignition.
(figure 5-4)
(1) Using suitable punch, remove pin (1), and remove flyweight and carrier assembly (2).
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open flame
or excessive heat. Flash point of solvent is 100°F -138°F (38°C-60°C).
(2) Clean flyweight and carrier assembly (2) in drycleaning solvent and dry thoroughly.
(3) Inspect flyweight and carrier assembly (2) and replace if worn, cracked or otherwise damaged.
(4) Install flyweight and carrier assembly (2) on shaft (3) and secure with pin (1).
5-12
|
|