5-15. Rockers (cont).
b. Inspection. (figure 5-15)
(1)
(2)
(3)
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open flame
or excessive heat. Flash point of solvent is 100°F -138°F (38°C-60°C).
Clean rockers in dry cleaning solvent and dry thoroughly.
Inspect rockers and rocker shaft for cracks or other signs of wear. Refer to Table 5-2 for wear limits.
Replace any component that is worn or otherwise damaged.
c.
Installation. (figure 5-15)
(1)
(2)
(3)
5-32
Position rockers (2) and (3) in cylinder head (7) and on pushrods (8).
Install rocker shaft (6) and secure with clip (5) and finger tighten adjusting screws (4) until rockers (2)
and (3) are snug.
Adjust valves (para. 5-16).
|