ARMY TM 9-2805-256-14 AIR FORCE TO 38G2-102-2 NAVY NAVFAC P-8-611-14E 6-8. Crankshaft  Assembly  (cont). b. Inspection.  (figure  6-5) WARNING Drycleaning  solvent  PD-680  used  to  clean  parts  is  potentially  dangerous  to  personnel  and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100°F-138°F (38°C-60°C). (1) Clean crankshaft (1) and bearing (2) with drycleaning solvent and dry thoroughly. (2) Inspect crankshaft and bearing for signs of excessive wear or other damage and replace as needed. Refer to table 6-2 for wear limits. (3) Inspect crankcase bearing cup (3) and replace if excessively worn or otherwise damaged. Refer to table 6-2 for wear limits. Figure 6-5. Crankshaft Inspection. NOTE Crankcase bearing cup exploded out of crankcase in figure 6-5 for clarity. 6-10


 