Custom Search
 
  
 
ARMY TM 9-2805-256-14 AIR FORCE TO 38G2-102-2 NAVY NAVFAC P-8-611-14E 6-9. Camshaft,  Camshaft  Axle,  and  Tappets  (cont). b. Removal  (figure  6-8) (1) (2) 6-14 WARNING Drycleaning  solvent  PD-680  used  to  clean  parts  is  potentially  dangerous  to  personnel  and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100°F–138°F (38°C-60°C). Clean  camshaft  (6),  camshaft  axle  (5)  and  tappets  (7)  with  drycleaning  solvent  and  dry  thoroughly. Inspect  all  components  for  signs  of  excessive  wear,  missing  or  damaged  gears  or  other  signs  of damage, and replace defective parts. Refer to table 6-2 for wear limits.


 