ARMY   TM   9-2805-256-14 AIR   FORCE   TO   38G2-102-2 NAVY   NAVFAC   P-8-611-14E 4-20.  Air   Cleaner   (cont). b.  Service.    Dry   (figure   4-9) (1) (2) (3) (4) (5) (6) 4 - 24 Loosen   two   retaining   screws   (1),   open   air   cleaner   assembly   (2),   and   remove   element   (3). W A R N I N G Drycleaning   solvent   PD-680   used   to   clean   parts   is   potentially   dangerous   to   personnel   and property.   Avoid   repeated   and   prolonged   skin   contact.   Do   not   use   near   open   flame   or excessive   heat.   Flash   point   of   solvent   is   100°F-138°F   (38°C-60°C). Clean   both   halves   of   air   cleaner   assembly   using   drycleaning   solvent. Clean   element   in   detergent   and   water. Dry   both   halves   of   air   cleaner   assembly   and   element   thoroughly. Position   element   (3)   in   air   cleaner   assembly   (2)   and   secure   with   two   retaining   screws   (1). Depress   reset   button   (4)   on   service   indicator   (5).


 