Custom Search
 
  
 
ARMY   TM   9-2805-256-14 AIR   FORCE   TO   38G2-102-2 NAVY   NAVFAC   P-8-611-14E 4-23.  Air   Cleaner   Element. This   task   covers: a.   Removal   (oil   bath) c.   Removal   (dry) b.   Installation   (oil   bath) d.    Installation    (dry) INITIAL   SETUP Tools Materials/Parts General   Mechanic’s   Tool   Kit   (Item   1,   Appendix   B) Rags,   Wiping   (Item   6,   Appendix   D) Solvent,    Drycleaning    (Item    7,    appendix    D) a.        .   (figure    4-13) (1) (2) (3) Open   two   retaining   clips   (1)   securing   lower   cup   (2)   and   remove. Pour   out   oil   into   suitable   container   and   remove   element   (3)   from   lower   cup   (2). W A R N I N G Drycleaning   solvent   PD-680   used   to   clean   parts   is   potentially   dangerous   to   personnel   and property.   Avoid   repeated   and   prolonged   skin   contact.   Do   not   use   near   open   flame   or excessive   heat.   Flash   point   of   solvent   is   100°F–138°F   (38°C-60°C). Clean   lower   cup   with   drycleaning   solvent   and   dry   thoroughly. b.      .    ( f i g u r e     4 - 1 3) (1)   Place   element   (3)   into   lower   cup   (2)   and   fill   with   oil   to   FULL   line. (2)   Install   lower   cup   (2)   and   secure   with   two   retaining   clips   (1). Figure   4-13.   Air   Cleaner   Element   Removal   and   Installation   (Oil   Bath). 4 - 32


 