Custom Search
 
  
 
ARMY TM 9-2805-257-14 AIR  FORCE  TO  38G2-103-2 NAVY NAVFAC P-8-612-14E 5-8. Governor Assembly (cont). c.    Repair. Breaker Point Ignition. (figure 5-4) (1) Using suitable punch, remove pin (1) and remove flyweight and carrier assembly (2) from shaft (3). WARNING Dry  cleaning  solvent  PD-680  used  to  clean  parts  is  potentially  dangerous  to  personnel and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100°F -138°F (38°C-60°C). (2) Clean flyweight and carrier assembly (2) with drycleaning solvent and dry thoroughly. (3) Inspect flyweight and carrier assembly (2) for wear and replace if worn or otherwise damaged. (4) Install flyweight and carrier assembly (2) on shaft (3) and secure with pin (1). 5-12


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business