ARMY TM 9-2805-257-14 AIR FORCE TO 38G2-103-2 NAVY NAVFAC P-8-612-14E b. Inspection. (figure 6-4) (1) (2) (3) WARNING Drycleaning  solvent  PD-680  used  to  clean  parts  is  potentially  dangerous  to  personnel  and property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 100°F-138°F (38°C–60°C). Clean  crankshaft  (1)  and  bearing  (2)  with  drycleaning  solvent  and  dry  thoroughly. Inspect  crankshaft  and  bearing  for  signs  of  excessive  wear  or  other  damage  and  replace  as  needed. Refer to table 6-2 for wear limits. Inspect crankcase bearing cup (3) and replace if excessively worn or otherwise damaged. Refer to table 6-2 for wear limits. Figure 6-4. Crankshaft Inspection. 6 -9


 