ARMY TM 9-2805-257-14
AIR FORCE TO 38G2-103-2
NAVY NAVFAC P-8-612-14E
Section Ill. OPERATION UNDER USUAL CONDITIONS
Paragraph
Page
2-9
Starting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-7
2-10
Stopping Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2-9
2-9. Starting Procedures. (figure 2-2)
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
Open fuel shutoff valve (1) on fuel filter (2).
Rotate choke control lever (3) counterclockwise and close choke.
On models 2A016 -2, 3, and -4, place throttle control (4) approximately 1/4 in. from idle position.
On models 2A016-2, 3, and -4, set ignition switch (5) to RUN position.
On models 2A016-3, -4, set inlet temperature control as follows:
(1) Above 50°F (10°C) push in handle (6).
(2) Between 50-25°F(10° (-4)°C), place handle (6) in center position.
(3) Below 25° (-4°C) pull out handle (6).
WARNING
Operation of the equipment presents a noise hazard to personnel in the area. The noise
level exceeds the allowable limits for unprotected personnel. Wear ear muffs or ear plugs
which were fitted by a trained professional.
Serious eye injury can result from the starting rope knot. Wear eye protection when pull
starting engine.
Wind starter rope (7) clockwise around starter flange (8) and pull briskly.
When the engine has started, rotate the choke control lever (3) clockwise until the choke is fully opened,
and the engine will continue to run.
NOTE
It maybe necessary on models 2A016-2, -3, and -4 to rotate the throttle control
counterclockwise to obtain a smooth idle.
Allow engine to warm-up for at least 3 minutes.
On models 2A016-2,
position.
Apply end item load.
-3, and -4, after warm-up, move throttle control counterclockwise to the full governed
Refer to End Item Operators Manual.
2-7
|
|